Overview
The XP40-P is an explosion-protected PTZ camera station designed for use in
hazardous areas in onshore, offshore, marine and heavy industrial environments.
It is constructed from electropolished 316L stainless steel for maximum
corrosion protection and is fitted as standard with a sunshield, integral wiper,
integral thermostatically controlled heater element and washer pump that links
to a 5, 10 or 25 litre container mounted up to 6m below the camera height.
Fitted as standard is a 36X or 37X ¼” or CCD module or 10X ” Super HAD CCD
module with ultra low-light sensitivity.
The XP40-P can be fitted as an option with an Oxalis X-NET integral SM/MM fibre
optic transmitter which can be used in conjunction with cabinet mounted Optical
Reciever Cards and X-Stream IP Encoders if required.
The XP range can be used in conjunction with Oxalis video management solutions
but is designed be compatible with most common video management systems.
Features
Explosion Protected for use in Onshore, Offshore, Marine & Heavy Industrial
Applications
ATEX, UL, IECEx, CSA, CCE, INMETRO, CNEX and GOST-R Approvals
Certified to the Latest Version of EN 60079-0 (2009) and EN 60079-31 (2009)
¼” or ” 10X Analogue Zoom Module Options
Integral SM/MM Fibre Transmitter Option
Integral Wiper and Washer Pump
Variable Speed Up to 45°/Sec Pan and 24°/Sec Tilt Speeds
All Electro-polished 316L Stainless Steel Construction
Fixed Cable Entry, No Trailing Cables
Integral Multi-Protocol Telemetry Receiver
Certification
Certified Part Number
2410-04/2420-01 /2410-05/2420-01 (Wiper)
Area Classification
Zones 1, 2, 21 and 22 (ATEX / IECEx / INMETRO) / Class 1, Zone 1 (North America
and Canada cLCus)
Equipment Coding (ATEX)
II 2 G Ex d op pr IIC T4 (T5 & T6 Available on Request) II 2 D Ex tb IIIC T135°C
Db IP6x
Equipment Coding (IECEx)
Ex d IIC T4/5* -60°C ≤ Ta ≤ +60°C Gb Ex tb IIIC T130°C Db IP6x
Equipment Coding (INMETRO)
Ex d IIC T4/5* -60°C ≤ Ta ≤ +60°C Gb Ex tb IIIC T130°C Db IP66/67
Equipment Coding (US - LCus)
Class 1 Zone 1 AEx d IIC T4/5* LC13A11396 Gb -60°C ≤Ta ≤ +60°C
Equipment Coding (Canada - cLC)
Ex d IIC T4/5* LC1311396 -60°C ≤Ta ≤ +60°C
Equipment Coding (China – CNEX)
Ex d IIC T4/T5/T6 GB / Ex d IIIC 135°C Db IP6X
Equipment Coding (Class – DIV)
Class I, Division 1, Groups B, C, D, -60°C≤Ta≤60°C / Class II, Division 1,
Groups E, F, G
Certificate Number (ATEX)
ITS08ATEX15950X / ITS08ATEX15927X
Certificate Number (IECEx)
IECEx ITS 10.0053X / IECEx ITS 10.0063X
Certificate Number (INMETRO)
TUV 12.1080 / TUV 12.1081
Certificate Number (US – LCus)
11396 – 1S – UL
Certificate Number (Canada – cLC)
11396 – 1S - CSA
Certificate Number (Russia – GOST-R)
POCC GB.ГБ.B00659
Certificate Number (India – CCE)
P306928/1/2
Certificate Number (China – CNEX)
132.2980X / 13.2981X
Certificate Number (Class – DIV)
11671 – 1S